For use with 5-foot 80 watt T5/HO fluorescent lamps
This ballast is available for the operation of one lamp on a 277V system and is ideal in fluorescent high-bay application. The ballast will also operate an 80 Watt long twin tube lamp, making it optimal for laboratory fume hoods and other applications requiring high illumination in limited spaces.
Like other Advance Mark 7 0-10V Dimming Ballast, the new unit dims lamps directly from a variety of compatible 0-10V controls, including occupancy sensors, ambient light sensors, and other automatic and manual controls. It is ideal for use with the most sophisticated total building management control systems, allowing substantial energy cost savings through such techniques as daylight harvesting and load shedding. The ballast's design allows for lighting control across branch circuits, reducing the number of controls required and maximizing flexibility of application.
|